Support
Support
Help with alveofit devices, software and deployments — for clinicians, technicians and programme teams

Getting help
Technical support is available by email at support@alveo.fit. Include your device serial number and a description of what you were doing when the issue occurred
For setup guides, calibration procedures and troubleshooting, see the knowledge base
alveoCare service agreements
Annual agreements add priority helpdesk access, on-site inspection, a replacement unit on loan during repair, and full hardware coverage
See it on your own patients.
A 30-minute session with a clinical specialist, on your devices and your workflow.
Product support detail
Comprehensive answers to technical, operational, and clinical queries regarding next-generation respiratory oscillometry
alveoflow is an advanced respiratory diagnostic device utilizing the Forced Oscillation Technique (FOT) to assess lung function. It measures airway mechanics during normal, quiet breathing, providing high-precision data on resistance and reactance without requiring forced expiratory maneuvers
Unlike spirometry, alveoflow is effort-independent. Standard spirometry requires a forced exhalation that can be coordination-dependent and physically demanding. alveoflow evaluates the entire bronchial tree during tidal breathing, allowing for a more accurate assessment of small airway resistance that spirometry might miss
Quiet-breathing assessments significantly reduce test fatigue and are far easier for patients to perform consistently. This is especially useful for pediatric patients, the elderly, or those with severe respiratory limitations, leading to better diagnostic compliance and more accurate long-term monitoring
Yes. Because alveoflow measures reactance and peripheral resistance, it is uniquely qualified to reveal early manifestations of small-airway disease (SAD) often associated with early-stage COPD or asthma, long before these changes affect spirometry parameters like FEV1
Technology & Measurement Parameters
FOT is a non-invasive diagnostic method that evaluates respiratory mechanics during normal quiet breathing by applying subtle pressure oscillations (5–40 Hz, extendable to 60 Hz) to the airway, measuring resistance and reactance without requiring forced maneuvers
Connect the alveoflow console to a grounded power source and press the primary power button on the side panel. The system will perform an automated 45-second diagnostic self-check and sensor array calibration before the interface indicator turns ready
alveoflow utilizes quiet-breathing assessments rather than forced maneuvers. Instruct the patient to breathe normally through the bacterial filter while maintaining a firm lip seal. The system automatically flag stable tidal breath cycles to ensure high-fidelity airway resistance measurements
A calibration verification should be performed at the start of each clinical session using the reference 2 cmH2O/L/s mesh. Navigate to the maintenance menu and follow the prompts to establish a baseline for your specific laboratory ambient conditions
Yes, Roundworks Technologies provides 24/7 technical support. You can reach our clinical specialists via the 'Help' icon within the AlveoCloud platform or by emailing support@alveo.fit for live assistance with hardware configuration or data integration
The exterior casing is sealed and can be disinfected using 70% IPA clinical wipes between patients. For deeper maintenance, the internal flow sensor is moisture-resistant and easily accessible for sterilization as detailed in the technical manual
alveoflow is designed for the highest safety levels. Because FOT uses quiet-breathing oscillometry, it avoids the forceful exhalation maneuvers that can be physically taxing or produce high-aerosol output, offering a safer alternative for vulnerable groups
The exterior housing and sensor unit should be wiped after each session with 70% isopropyl alcohol or a clinical-grade disinfectant wipe. Always use a new single-use bacterial/viral filter (BSPF) for every patient to prevent cross-contamination
While the system performs an automated daily calibration check using the provided reference resistance, we recommend a certified factory recalibration every 12 months. This ensures long-term accuracy and maintains compliance with clinical ISO 13485 standards
Technical assistance is available via email at support@alveo.fit. For immediate troubleshooting, use the alveoflow Dashboard to generate a diagnostic log report which can be remotely reviewed by our clinical specialists for faster resolution
alveoConnect® web application is designed to be compatible with various web browsers, ensuring accessibility for users
alveoConnect® web application is designed to be compatible with various web browsers, ensuring accessibility for users. While the application is generally supported in every browser, it’s worth noting that the spirometry feature is exclusively available in Google Chrome. Users are encouraged to use Chrome for optimal functionality when utilizing the spirometry feature within the alveoConnect® web application
alveoConnect® is designed to provide compatibility across a broad spectrum of web browsers, ensuring users can access and utilize the platform seamlessly. It aims to support the latest versions of popular browsers such as Google Chrome, Mozilla Firefox, Microsoft Edge, Safari, and others. Users are encouraged to use the latest browser versions for the best experience, as alveoConnect® is designed to be compatible with a diverse range of web browsers
Thank you for your understanding and we look forward to offering you a seamless experience on alveofit®
We would like to inform our valued users that our application is currently available on Android devices. However, it is available for iOS devices at this time. We are committed to providing a high-quality experience and are considering expanding our platform availability in the future. Stay tuned for updates and thank you for your understanding
The alveofit® application is designed to work with Android devices running version 8.0 (Oreo) or higher. Checking Your Android Version: Users can check their Android version by going to Settings > About Phone > Software Information on their device. If your version is below 8.0, an update may be required to use alveofit. Note: Users with devices running Android versions older than 8.0 may not be able to install or run the alveofit® app effectively. We encourage users to consider updating their device software or using a compatible device to access all the features of alveofit®
1. Chrome Optimization: The alveoConnect® Portal is optimized for Google Chrome, ensuring a smooth and efficient user experience. This means when you access the portal using Chrome, you can expect enhanced functionality, speedy performance, and a user-friendly interface
3. Cross-Platform Accessibility: Chrome’s cross-platform nature allows users to access the alveoConnect® Portal from various devices, including desktops, laptops, and tablets, provided they are using the Chrome browser. This ensures consistent access and experience regardless of the device used
4. Why Chrome: Google Chrome is known for its robust security features, fast performance, and frequent updates. These attributes make it an ideal choice for accessing web-based platforms like the alveoConnect® Portal, ensuring data is transmitted securely and efficiently
5. How to Access: To access the alveoConnect® Portal, users should navigate to the portal’s URL using the Chrome browser. Once logged in, the portal will automatically detect and sync with the alveoair® device, allowing for real-time monitoring and management
6. Technical Requirements: Users should ensure their Chrome browser is up to date to take full advantage of all the features and security updates. The alveoConnect® Portal is designed to work with the latest versions of Chrome for optimal performance
The alveoMD® application is designed to work with Android devices running version 8.0 (Oreo) or higher. Checking Your Android Version: Users can check their Android version by going to Settings > About Phone > Software Information on their device. If your version is below 8.0, an update may be required to use alveoMD
Note: Users with devices running Android versions older than 8.0 may not be able to install or run the alveoMD® app effectively. We encourage users to consider updating their device software or using a compatible device to access all the features of alveoMD®